Therma-Tru Shingle, Tile & Metal Roofing in Hollywood: What to Know First
Therma-Tru shingle, tile, and metal roofing in Hollywood is roof system work we handle as an independent Therma-Tru service provider, typically completed within one to three days depending on scope and material availability. Most Hollywood homeowners call us when a Therma-Tru roof component has failed after years of salt air and storm cycles, not for a full tear-off. Pricing runs honest and itemized: you’ll see the line items before we start, and the estimate is free. If you own a Therma-Tru roof system in Hollywood and something is leaking, lifting, or showing rust, call (863) 334-2933 and a live person will answer.
This page is for homeowners who already have Therma-Tru roofing products on their house and need straight answers about repair, replacement, and what it costs in this market. We’ll cover the failure modes we actually see here, the parts decisions that matter, and what a proper fix looks like.
How Therma-Tru Products Fail - and How We Fix Them
Therma-Tru is better known for doors, but their roofing lines show up consistently in Hollywood’s older subdivisions and a few newer builds. Here is what we find when we get called out:
- Therma-Tru Classic-Craft Shingle Overlay Separation: The asphalt shingle overlay on Therma-Tru’s Classic-Craft series is factory-bonded, and after a decade of Hollywood’s wet season followed by brutal August sun, that bond starts to let go at the edges. Water gets under the shingle layer and sits against the substrate. The fix is removing the compromised overlay, treating any surface oxidation, and re-bonding with a marine-grade adhesive rated for continuous moisture exposure. Patching over it just traps the water.
- Tile Cap Lifting on Therma-Tru Tile Series: We regularly see tile caps on Therma-Tru’s tile-look roofing products lift at the hips and ridges in Hollywood, FL. The cause is almost always thermal cycling: the tile expands and contracts at a different rate than the metal flashing beneath it. The cap screws back down easily, but if you don’t replace the worn neoprene washers at the same time, it lifts again within two seasons. We replace every washer on every cap we touch.
- Metal Panel Galvanic Corrosion at Fastener Points: This is the most common Therma-Tru metal roofing failure in Hollywood, and it is almost entirely avoidable. When a previous installer used standard steel fasteners instead of the coated fasteners Therma-Tru specifies, salt air creates galvanic corrosion at every penetration point. In Hollywood’s coastal humidity, those fasteners start to rust within five to seven years. Our fix is removing the corroded fasteners, treating the surrounding metal, and reinstalling with the correct coated hardware. If the panel itself has thinned, that section gets replaced.
- Flashing Gaps Where Therma-Tru Roofing Meets Therma-Tru Door Frames: This is a failure point specific to Therma-Tru installs: the roof flashing that meets Therma-Tru door frames often gets installed too tight, and the natural movement of the door frame under wind load tears the flashing at the corner. We see this most often on south-facing elevations in Hollywood where afternoon storms hit hardest. The proper fix is a stepped flashing detail that allows independent movement, with sealant applied to the lap, not the edge.
- Underlayment Degradation Under Tile Systems: With tile roofing, the tile is the armor, but the underlayment is what actually keeps the water out. On older Therma-Tru tile installs in Hollywood, we find underlayment that has dried out and cracked at the eaves. The tiles look fine from the ground. The leak is real, though. When we lift tiles to inspect and find degraded underlayment, we replace it in sections rather than spot-patching, because the failure pattern is consistent across the whole plane.
Our Therma-Tru Shingle, Tile & Metal Roofing Process
Here is how a Therma-Tru roofing job goes from first call to final walkaround:
- 1
Call and schedule. A live person answers at (863) 334-2933. We set a visit window and show up when we say we will.
- 2
Full roof and opening inspection. We do not quote a roof repair from the driveway. One of our background-checked, uniformed techs inspects the roof surface, penetrations, flashing, and the areas where roofing meets doors and windows. Measurements are taken twice.
- 3
Written diagnosis and parts decision. We lay out what is failing, why, and whether OEM Therma-Tru components or a quality aftermarket equivalent makes more sense. You see both options on paper, side by side, with pricing.
- 4
The work. Repairs or replacement sections are completed with the detail work that prevents the same failure from returning: coated fasteners, proper flashing laps, fresh washers on every cap.
- 5
Water test and visual verification. We water-test the repaired area before we leave and walk the roof with you when it is safe to do so. No surprises on the bill because the price was fixed before we started.
- 6
Warranty registration and the Done Right Promise. We register both manufacturer warranty layers in writing before the truck leaves the driveway, and our own workmanship is covered for 90 days with no paperwork fights.
What Therma-Tru Shingle, Tile & Metal Roofing Costs in Hollywood
Straight numbers based on what we quote in Hollywood, FL:
- Shingle overlay repair (Classic-Craft series): $275-$575 per section depending on square footage and substrate condition.
- Tile cap re-securing with new washers: $180-$425 for a typical residential hip and ridge run.
- Fastener replacement and corrosion treatment (metal panels): $350-$750 depending on the number of affected penetrations.
- Flashing replacement at roof-to-door intersections: $300-$650 per transition, more if custom metal fabrication is needed.
- Underlayment section replacement under tile: $800-$1,900 for a typical 200-400 square foot section, depending on tile removal complexity and disposal.
What moves the price: roof pitch and access, how many tiles need to come off and go back, the condition of the substrate underneath, and whether OEM Therma-Tru components are available or we need to match with an equivalent. Hollywood’s humid climate means hidden corrosion can be worse than it looks from the ground, which is why we quote from the roof, not from a satellite image. The estimate is free, and it is fixed: the number on the written quote is the number on the invoice. Call (863) 334-2933 to schedule.
Why Hollywood Homeowners Call TruePane Windows & Doors for Therma-Tru Work
We are not a Therma-Tru dealer, and we will not pretend to be one. We are an independent Therma-Tru service provider, and that is exactly what most Hollywood homeowners need: someone who can work on a Therma-Tru roof system without a franchise manual. Dale Kessler grew up in the Liberia neighborhood of Hollywood, and he has been measuring, setting, and troubleshooting building products in South Broward for going on three decades. His father spent weekends resealing jalousie frames against the Atlantic. That is the standard we work to: if it is not done right, we make it right, in writing, for 90 days. Every job is covered by The Keystone Standard. Both manufacturer warranty layers get registered before we leave. And when Therma-Tru components need to work alongside PGT, CGI, CWS, or ES Windows products, we have the cross-brand experience to handle that without finger-pointing. One call, one company, one square deal.
FAQs
No, not when the repair is done correctly. Independent repair does not automatically void a Therma-Tru warranty, but improper installation or the wrong materials can. That is why we register both manufacturer warranty layers in writing and install to Therma-Tru’s documented installation standards on every job. We will not use a part or fastener that could give a manufacturer a reason to deny a future claim. Call (863) 334-2933 if you want us to check your specific warranty language before any work begins, and the estimate is free.
For active leaks, we prioritize inspection and temporary mitigation, and in most cases we complete the permanent repair within one to three business days of the first visit. Material availability for some Therma-Tru OEM components can extend that, which is why we carry common fasteners, washers, and flashing stock on the truck. If the roof is actively leaking, call (863) 334-2933 and a live person answers, day or night.
The decision comes down to two things: the condition of the underlayment and the condition of the fastening system. If the underlayment under the tile is cracked and degraded across most of the plane, replacing sections now is throwing money at a problem that will move. If the tiles themselves are sound and the underlayment is intact, a targeted repair is the right call. We will show you what we find on the roof, and we will not recommend replacement unless we can show you why it is necessary. A repair quote is free, and a replacement quote is free too.
We source OEM Therma-Tru components through our supplier network and use quality aftermarket equivalents only where they equal or exceed the OEM spec. Fasteners and flashing are the two areas where an honest aftermarket part can outperform an OEM part in Hollywood’s salt air. You will see the brand and the spec on the written quote before we install anything. Call (863) 334-2933 for an exact quote on your specific roofing issue.
Yes, we repair leaks and corrosion on metal roof panels, standing seam profiles, and the flashing details that connect metal roof runs to doors, windows, and other roof planes. Metal roof leaks in Hollywood are rarely the panel itself; it is the fasteners, the laps, or the transitions that fail first. We find the actual source before we quote anything.
Written by Dale Kessler, Owner, TruePane Windows & Doors at TruePane Windows & Doors, serving Hollywood and nearby areas.
Six Reasons Homeowners Choose TruePane Windows & Doors
Impact systems engineered to design pressures up to +/-100, matched to your wind zone - your openings hold when the storm arrives.
Low-E insulated impact glass from our manufacturer lines commonly cuts monthly cooling bills 20-30%.
Laminated impact glass shuts out up to 40% of outside noise - traffic, neighbors, weather.
Monitoring services run $30-90 a month. Laminated impact glass resists forced entry around the clock, with no subscription.
Florida homeowners average around 25% savings on the windstorm portion of their policy after protecting every opening - some homes qualify for more.
A full impact package upgrades curb appeal, buyer confidence and appraised value in one project.



Before
After
Before
After
Before
After